databaseklion.blogg.se

Time code clocker
Time code clocker













time code clocker
  1. #Time code clocker generator#
  2. #Time code clocker manual#

Pressing Go will manually advance the Cuelist. You can also use the Go and Pause/Back buttons for a timecoded Cuelist.

time code clocker

If a Follow or Wait trigger has been set for a cue, it will override any timecode trigger time that has been set for that cue. Timecode and other TriggersĪ timecoded Cuelist will still take advantage of other trigger types such as Follow and Wait.

#Time code clocker manual#

If you wish, you can reset a trigger time to manual by selecting the desired cue timing(s) and pressing -(minus minus) Enter. To delete 5 minutes from an individual or range of cues select the cue timing(s) and press - 5 0 0 0 0 Enter.To add 5 minutes to an individual or range of cues select the cue timing(s) and press + 5 0 0 0 0 Enter.You can increment or decrement an individual or selected range of cues by using the + and - buttons. To set the time to 11 hours, press 1 1 0 0 0 0 0 0 Enter.To set the trigger time to 1 second and 15 frames press 1 1 5 Enter.The command line will read Set Cue xx TC Time With Edit Mode on, press or click the legend Manual Trigger on the cue you wish change.Recalling that the format for SMPTE timecode is HH:MM:SS:FF, use the following steps to set the trigger time: ONYX allows you to change the trigger time by manually entering the values for hours, minutes, seconds and frames in much the same way you would change the time of a standard cue. When you first set the cuelist to the Timecode type, all of the times will be listed as “Manual Trigger.” This means that timecode will not execute the cue.

time code clocker

Any cues that follow that have a timecode trigger would then be executed. This would be a manual cue with no information in it. In this instance, a mark cue is a cue that contains no information, it simply starts the Cuelist.Īn example would be to record a “.5” cue before the first cue in your Cuelist. This is accomplished by recording a “mark” cue. You must already be running a cue in the Cuelist for timecode to trigger later cues. In order for timecode to trigger a Cuelist, that Cuelist must be active. Working with the Timecode Cuelist Setting a Mark Cue Pressing this display will allow you to quickly switch types of Timecode or Scan for MIDI devices: When Timecode is live, you will also see a display near the top right of the main ONYX window. This is useful if you want some cues to follow timecode, but some cues to be triggered manually. Pressing Go on the Cuelists Go button will simply advance the Cuelist without capturing the timecode time. When selected and a timecode source is present, pressing the console's Main Go button will automatically capture the timecode time that the cue was executed and save it with the cue for later playback. If turned on while timecode is running, the Cuelist will advance to the last executed cue as determined by the timecode value. When turned off, incoming timecode will be ignored.

#Time code clocker generator#

When set to on, the Cuelist will “listen” to the selected timecode generator and the Cuelist will follow the timecode. Pressing this button will cause the clock to reset to 00:00:00:00 The stop button is used to stop the internal timecode generator. The Pause button is used to stop the internal timecode generator without resetting it to zero. The Play button is used to start SMPTE when using the internal timecode generator. HH is hours, MM is minutes, SS is seconds and FF is frames. This is where the received timecode is displayed. You will note several buttons available in "Cuelist Values" for the Timecode Cuelist: Button You can set up the Timecode preferences in the Main Menu. When using timecode in an X-Net session, the Primary ONYX device will accept and follow the timecode given. ONYX allows for the connection to an external time clock for the synchronized triggering of cues.















Time code clocker